37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
| Attributes | |
| ACN | 596047 |
| Time | |
| Date | 200309 |
| Day | Tue |
| Local Time Of Day | 0601 To 1200 |
| Place | |
| Locale Reference | airport : zzz.airport |
| State Reference | US |
| Altitude | agl single value : 0 |
| Environment | |
| Light | Daylight |
| Aircraft 1 | |
| Operator | common carrier : air carrier |
| Make Model Name | B767-300 and 300 ER |
| Operating Under FAR Part | Part 121 |
| Flight Phase | ground : takeoff roll ground : maintenance |
| Flight Plan | IFR |
| Person 1 | |
| Affiliation | company : air carrier |
| Function | maintenance : technician |
| Qualification | technician : powerplant technician : airframe |
| ASRS Report | 596047 |
| Person 2 | |
| Affiliation | company : air carrier |
| Function | flight crew : captain oversight : pic |
| Events | |
| Anomaly | aircraft equipment problem : critical maintenance problem : non compliance with mel non adherence : published procedure non adherence : far |
| Independent Detector | other flight crewa other flight crewb |
| Resolutory Action | flight crew : diverted to another airport |
| Consequence | other other |
| Factors | |
| Maintenance | contributing factor : schedule pressure contributing factor : manuals performance deficiency : non compliance with legal requirements performance deficiency : logbook entry |
| Supplementary | |
| Problem Areas | Maintenance Human Performance Aircraft Chart Or Publication |
| Primary Problem | Maintenance Human Performance |
Narrative:
Adp (air driven pump) inoperative per MEL 29-04A. Aircraft ground interrupt due adp completely inoperative. Changed over to 29-03 and retained fix at 7 days. Did not need pump as aircraft routed domestic. No international flight.
Original NASA ASRS Text
Title: A B767-200ER WAS DISPATCHED ON AN OVERWATER TRIP RETURNED TO THE FIELD WITH THE AIR DRIVEN HYD PUMP DEFERRED PER THE MEL.
Narrative: ADP (AIR DRIVEN PUMP) INOP PER MEL 29-04A. ACFT GND INTERRUPT DUE ADP COMPLETELY INOP. CHANGED OVER TO 29-03 AND RETAINED FIX AT 7 DAYS. DID NOT NEED PUMP AS ACFT ROUTED DOMESTIC. NO INTL FLT.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.