37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
| Attributes | |
| ACN | 516738 |
| Time | |
| Date | 200106 |
| Day | Fri |
| Local Time Of Day | 0601 To 1200 |
| Place | |
| Locale Reference | airport : cno.airport |
| State Reference | CA |
| Altitude | msl single value : 6500 |
| Environment | |
| Flight Conditions | VMC |
| Light | Daylight |
| Aircraft 1 | |
| Controlling Facilities | tracon : sct.tracon artcc : zab.artcc |
| Operator | general aviation : personal |
| Make Model Name | Skyhawk 172/Cutlass 172 |
| Operating Under FAR Part | Part 91 |
| Flight Phase | cruise : level |
| Flight Plan | None |
| Person 1 | |
| Affiliation | other |
| Function | flight crew : single pilot |
| Qualification | pilot : private |
| Experience | flight time last 90 days : 10 flight time total : 195 flight time type : 10 |
| ASRS Report | 516738 |
| Person 2 | |
| Affiliation | government : faa |
| Function | controller : approach |
| Events | |
| Anomaly | aircraft equipment problem : critical non adherence : published procedure other anomaly |
| Independent Detector | aircraft equipment other aircraft equipment : eng |
| Resolutory Action | flight crew : overcame equipment problem flight crew : returned to intended or assigned course flight crew : regained aircraft control |
| Supplementary | |
| Problem Areas | Flight Crew Human Performance |
| Primary Problem | Flight Crew Human Performance |
Narrative:
Had power decline intermittency at 6500 ft leading to engine shutdown in about 30 seconds. Started emergency procedures. When I tried to restart engine, switched from tank #1 to tank #2. Power restored. This is per manual, for aircraft. I lost a few hundred ft elevation before restoring power. I will modify emergency procedure for this aircraft to switch tanks first, then the power outage would have lasted 2 seconds.
Original NASA ASRS Text
Title: A C172 PVT PLT LOSES PWR IN HIS ENG AND STARTS THE EMER PROCS DURING SOME ALT LOSS. ENG RESTARTS WHEN TANK SELECTOR MOVED TO TANK #2, NEAR CHINO, CA.
Narrative: HAD PWR DECLINE INTERMITTENCY AT 6500 FT LEADING TO ENG SHUTDOWN IN ABOUT 30 SECONDS. STARTED EMER PROCS. WHEN I TRIED TO RESTART ENG, SWITCHED FROM TANK #1 TO TANK #2. PWR RESTORED. THIS IS PER MANUAL, FOR ACFT. I LOST A FEW HUNDRED FT ELEVATION BEFORE RESTORING PWR. I WILL MODIFY EMER PROC FOR THIS ACFT TO SWITCH TANKS FIRST, THEN THE PWR OUTAGE WOULD HAVE LASTED 2 SECONDS.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.