37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
| Attributes | |
| ACN | 1586779 |
| Time | |
| Date | 201810 |
| Local Time Of Day | 0601-1200 |
| Place | |
| Locale Reference | ZZZ.Airport |
| State Reference | US |
| Environment | |
| Light | Dawn |
| Aircraft 1 | |
| Make Model Name | Regional Jet 200 ER/LR (CRJ200) |
| Operating Under FAR Part | Part 121 |
| Flight Phase | Taxi |
| Component | |
| Aircraft Component | APU |
| Person 1 | |
| Function | Technician |
| Qualification | Maintenance Airframe Maintenance Powerplant |
| Events | |
| Anomaly | Aircraft Equipment Problem Critical Flight Deck / Cabin / Aircraft Event Smoke / Fire / Fumes / Odor |
Narrative:
While the aircraft was being towed and I received the signal; I started the APU in accordance with crj 200 [maintenance procedure]. The egt was around 350 but the RPM only went to 24. [Maintenance personnel] opened the door and told me to shutdown; we have an APU fire. (No fire indication was indicated on displays) I properly shutdown; set brakes; and got out of the aircraft.
Original NASA ASRS Text
Title: CRJ200 Maintenance Technician reported an APU fire was observed during aircraft tow.
Narrative: While the aircraft was being towed and I received the signal; I started the APU in accordance with CRJ 200 [Maintenance Procedure]. The EGT was around 350 but the RPM only went to 24. [Maintenance personnel] opened the door and told me to shutdown; we have an APU fire. (No fire indication was indicated on displays) I properly shutdown; set brakes; and got out of the aircraft.
Data retrieved from NASA's ASRS site and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.